Development of Data Packages on the Human Visual Response with Electro-Optical Displays.
Abstract
The prototype electro-optical systems being charactered contain both image intensifiers (I2s) and cathode ray tubes (CRTs). This quarter attention was focused on I2 characterizations. The efficacy of using a color television monitor with only the red color channel activated for I2 performance measurements was investigated instead of a typical tungsten lamp with a 2856K color temperature. A tungsten lamp operated at a 2856K color temperature with an opal glass Lambertian diffusing window and variable intensity mechanism is typically used as the visible and near-infrared light source for I2 performance measurements. The use of a color monitor as a substitute for the tungsten lamp was investigated, since the tungsten lamp has several undesirable characteristics.
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 30, 1992
- Accession Number
- ADA316419
Entities
People
- Robert W. Verona
Organizations
- Universal Energy Systems