Development of Data Packages on the Human Visual Response with Electro-Optical Displays.
Abstract
The prototype electro-optical systems that are being characterized contain both image intensifiers (I2s) and cathode ray tubes (CRTs). This quarter's efforts were divided between the I2 and CRT characterizations, This quarter's efforts also investigated the efficacy of using a color television monitor with only the red color channel activated for image intensifier (I2) performance measurements instead of a typical tungsten lamp with a 2856K color temperature. After proving that the monitor could be used interchangeably with the lamp, the monitor was substituted for the tungsten lamp for some of the psychophysical tests when applicable. Another objective of this quarter was the development of a dynamic modulation transfer function (DMTF) measurement capability.
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 26, 1993
- Accession Number
- ADA316420
Entities
People
- Robert W. Verona
Organizations
- Universal Energy Systems