Final Report of the Gamma-Ray Leakage from the Aberdeen Pulse Radiation Facility (APRF) Reactor.
Abstract
The gamma-ray leakage from the Aberdeen Pulse Radiation Facility (APRF) fast-burst reactor has been measured. A BGO spectrometer was used to measure spectrum, and a Geiger counter was used to measure dose. The two detectors were consistent, but measured about 60 percent more dose than indicated by calculation.
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1995
- Accession Number
- ADA317137
Entities
People
- Craig R. Heimbach