Thermal Management Research Studies. Volume 3. Heat Pipe in High-G Environment: Analysis, Design and Testing.
Abstract
This report presents the details of a spin table test facility developed for testing heat pipes and other heat transfer experiments under high acceleration conditions. A drive system capable of variable spin up and spin down acceleration rates to simulate aircraft G-forces encountered during flight maneuvers is described. Also included are details on calorimetric testing, remote computer control operation and multichannel data acquisition capabilities of the spin table. The effects of G-load on a heat pipe performance were analyzed with reference to the influence of bond number and operating temperature. The steady state test results of a flexible copper-waterheat pipe under transverse accelerations up to 10G are presented along with those analytically predicted.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 11, 1996
- Accession Number
- ADA323828
Entities
People
- Rengasamy Ponnappan
Organizations
- Universal Energy Systems