Leaky Coaxial Cable Sensor Slot/Sealant Configuration Performance Monitoring.
Abstract
A new slot/sealant configuration has been recommended for the installation of leaky coaxial cable sensor systems. This report documents the field performance of a trial installation at Westover Air Force Base, Massachusetts. Visual observations alter 2 years of service indicate that the new slot/sealant configuration is performing satisfactorily.