Removal of Waste Anesthetics Exhaust.

Abstract

This report describes the use of Canadian military carbon-containing canisters (C2 and C7) in removing waste anesthetics exhaust. The efficiency and service-life of these canisters are presented. In addition, the use of other adsorbents and some commercially-available occupational health and safety canisters for this purpose is also discussed.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1995
Accession Number
ADA336364

Entities

People

  • B. V. Lacroix
  • D. G. Bailey
  • R. T. Poirier
  • S. H. Liang

Tags

Communities of Interest

  • Biomedical
  • C4I

DTIC Thesaurus Topics

  • Air Supplies
  • Anesthesia
  • Anesthetics
  • Boiling Point
  • Chemical Synthesis
  • Chemistry
  • Cyanides
  • Dielectric Gases
  • Flow Rate
  • Gas Masks
  • Health Services
  • Impregnation
  • Medical Personnel
  • Military Hospitals
  • Nitrogen Oxides
  • Occupational Safety And Health
  • Physical Properties

Readers

  • Environmental Engineering.
  • Rocket Propulsion.
  • Systems Analysis and Design