Lot Variability of Sofnolime 408 Carbon Dioxide Absorbent When Tested in the Cold

Abstract

NEDU performed quality assurance tests on 18 lots of Sofnolime 408, a large grain sodalime made by Molecular Products. CO2 absorption activity using the standard NATO tubs test was performed at initial absorbent bed temperatures of approximately 32 deg F. Moisture analyses and sieve tests were also performed on each sample. Absorption test breakthrough in the chilled bed occurred at an average of 7 min, compared to the usual 40 min duration under ambient conditions. Absorption activity was negatively correlated with increasing moisture content, and positively correlated with an increasing percentage of absorbent retained on the #8 sieve.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Aug 01, 1998
Accession Number
ADA355578

Entities

People

  • J. R. Clarke
  • L. D. Thompson
  • R. J. Godgrey Jr.

Organizations

  • United States Navy Experimental Diving Unit

Tags

DTIC Thesaurus Topics

  • Absorption
  • Abstracts
  • Bench Tests
  • Carbon Dioxide
  • Chi Square Test
  • Classification
  • Cold Water
  • Low Temperature
  • Materials
  • Moisture
  • Moisture Content
  • Respiration
  • Specifications
  • Standards
  • Statistical Analysis
  • Test Beds
  • Water

Readers

  • Materials Science
  • Mathematics or Statistics