BULLPUP Chemical Overpack Container Evaluation

Abstract

The U.S. Army Defense Ammunition Center (DAC), Validation Engineering Division (SIOAC-DEV), was tasked by the U.S. Army Chemical and Biological Defense Command (CBDCOM) to perform an engineering evaluation on the BULLPUP chemical overpack container. It was found that the proposed container modifications and 200 in-lbs of torque applied to the Tee-bolts produce a container with adequate leak integrity. This report contains the results of this evaluation.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jan 01, 1998
Accession Number
ADA356468

Entities

People

  • Bradley J. Haas

Organizations

  • Defense Ammunition Center

Tags

Communities of Interest

  • Biomedical

DTIC Thesaurus Topics

  • Ammunition
  • Butyl Rubber
  • Central Nervous System
  • Chemical Properties
  • Containers
  • Digestive System Processes
  • Engineering
  • Fire Fighting
  • Flash Point
  • Health Services
  • Manufacturing
  • Materials
  • Medical Personnel
  • Neoplasms
  • Rubber Gaskets
  • Test And Evaluation
  • Validation

Readers

  • Critical Infrastructure Protection in CBRN and WMD Threats.
  • Logistics and Supply Chain Management.