Investigation of Single Stage Incineration of the 50 MW Electrogasdynamics Facility NOx Contaminated Effluent
Abstract
This experiment was conducted to determine the feasibility of eliminating the noxious NO(x) in the 50 MW Electrogasdynamics Facility effluent by incineration. During the experiment, almost all of the NO2 was converted to NO, but none of the NO was reduced to N2 and 02. Since the results of this experiment demonstrated that direct single stage incineration of the NO(x) laden 50 MW Facility effluent does not reduce the total NO(x) exhausted, it is concluded that the direct single stage incineration process will not provide effective air pollution control for the 50 MW Electrogasdynamics Facility.