Final Site-Specific Technical Report for the Evaluation of Thermatrix GS Series Flameless Thermal Oxidzer for Off-Gas Treatment of Trichloroethene Vapors at Building 181 Air Force Plant 4, Texas
Abstract
The Air Force Center for Environmental Excellence (AFCEE) has sponsored an ongoing program to promote the use of cost-effective soil vapor treatment technologies in conjunction with soil vapor extraction (SVE) for remediation of fuel- and solvent-impacted sites. On September 20, 1995, Parsons Engineering Science, Inc. (Parsons ES) received formal notice to proceed from HSD/PKVDA at Brooks Air Force Base (AFB) under Contract F41624-94-D-8136, Delivery Order 28, to implement a statement of work (SOW) that outlines requirements to provide services to support environmental air conformity through evaluation of the flameless thermal oxidation (FTO) vapor-phase treatment technology for SVE off-gas abatement at various Air Force base sites worldwide. Thermatrix, Inc. (Thermatrix) of Knoxville, Tennessee is an AFCEE directed subcontractor providing the FTO treatment system to be evaluated during the demonstrations. Thermatrix was selected in the Broad Agency Announcement (BAA) for Technology Demonstration for technology evaluation and cost performance of their GS Series FTO system. A technology demonstration was designed by Parsons ES to determine the applicability of using FTO technology for treatment of extracted soil vapors containing chlorinated and non-chlorinated volatile organic compounds (VOCs). Three Air Force installations were identified for demonstrating the FTO system, including Building 181 at AFP 4, Fort Worth, Texas, which is the subject of this report.
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 01, 1998
- Accession Number
- ADA382616
Entities
People
- Douglas C. Downey
- Mark J. Vessely
- Peter R. Guest
- Steven R. Archabal
Organizations
- Parsons Corporation