Evaluation of Thermal Stability Improving Additives for Juel Fuel in Both Laminar and Turbulent Flow Test Units
Abstract
All three TSIAs reduce the amount of thermal deposits, measured via carbon burnoff, in both laminar and turbulent test units for the three (3) different base fuels tested. For the laminar test unit, Betz 8Q462 shows better deposit inhibition than MDA by a narrow margin. Therefore, MDA shows a ysnergistic effect when added to the Betz 8Q406 (to produce Betz 8Q462) in the laminar unit.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 27, 2000
- Accession Number
- ADA383363
Entities
People
- Clarence J. Nowack
- John E. Colbert
Organizations
- Naval Air Warfare Center