Results of Bioventing System Monitoring at Sites ST12-A and ST12-B, Waikakalaua Fuel Storage Annex (FSA), Hickam Petroleum, Oils, and Lubricants (POL) System, Hawaii

Abstract

This letter presents the results of the bioventing system monitoring performed by Parsons Engineering Science, Inc. (Parsons ES) in December 1996 at Sites ST 12-A and ST 12-B, located at the Waikakalaua Fuel Storage Annex (FSA) administered by Hickam Air Force Base (AFB), Hawaii. Soil gas samples were collected and in situ respiration testing was performed by Parsons ES between 10 and 23 December 1996 to assess the extent of remediation completed during approximately 3.5 years of air injection bioventing at Site ST 12-A and 1 year of air injection bioventing at Site ST 12- B. The purpose of this letter is to summarize remediation activities to date, present the results of the December 1996 system monitoring event and compare them with the results of previous monitoring events, and to outline future remediation activities planned for Sites ST12-A, ST12-B, and ST1O, which is located at Valve Pit 17 on the Hickam POL pipeline near Kipapa FSA.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Feb 28, 1997
Accession Number
ADA384530

Entities

Organizations

  • Parsons Corporation

Tags

DTIC Thesaurus Topics

  • Air Force
  • Air Force Facilities
  • Aromatic Hydrocarbons
  • Aviation Gasoline
  • Biodegradation
  • Chemical Synthesis
  • Chemistry
  • Composite Materials
  • Contracts
  • Department Of Defense
  • Engineering
  • Environmental Protection
  • Fuels
  • Hydrocarbons
  • Internal Combustion Engines
  • Monitoring
  • Petroleum

Fields of Study

  • Environmental science

Readers

  • Agricultural Chemistry/Soil Science
  • Canadian European Scientific Immigration and Epilepsy Clearance Studies
  • Clinical Trial Research.