Operation and Maintenance Manual, Record Drawings, and Summary of Initial Results for the Expanded Bioventing System Installed at Site SS-41 (Former Fuel Pumping Station Number 3), Charleston AFB, SC

Abstract

This letter transmits three copies of the Operation and Maintenance (O&M) Manual prepared for the expanded bioventing system recently installed at Site SS-4l (Former Fuel Pumping Station No. 3, Building 93), Charleston Air Force Base (AFB), South Carolina. Appendix A of the O&M Manual contains record drawings for the installed system. This letter report also provides a summary of the work performed by Parsons Engineering Science, Inc. (Parsons ES) at the site from February through June 1997. Included in this report are the initial bioventing system operating parameters and sampling results. Copies of this letter and the O&M Manual also have been sent to Mr. Al Urrutia, the point of contact at Charleston AFB.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Oct 28, 1997
Accession Number
ADA385067

Entities

Organizations

  • Parsons Corporation

Tags

Communities of Interest

  • Biomedical

DTIC Thesaurus Topics

  • Air Force
  • Air Force Facilities
  • Aromatic Hydrocarbons
  • Contractors
  • Cyclic Hydrocarbons
  • Flow Rate
  • Fuels
  • Groundwater
  • Hydrocarbons
  • Measurement
  • Organic Compounds
  • Pressure Distribution
  • Pumping Stations
  • Shallow Water
  • South Carolina
  • Vapor Phases
  • Volatile Organic Compounds

Readers

  • Climatology
  • Defense Financial Management and Audit.
  • Groundwater Contamination Remediation.