Extended Bioventing Testing Results for Buildings 2034/2035, Fairchild AFB, Washington

Abstract

This letter presents the results of the bioventing system monitoring performed by Parsons Engineering Science, Inc. (Parsons ES) in October 1997 at Buildings 2034/2035 at Fairchild Air Force Base (AFB), Washington. Soil gas samples were collected and in situ respiration testing was performed by Parsons ES between 1 and 3 October 1997, to assess the extent of remediation completed during 1 year of full-scale air injection bioventing. The purpose of this letter is to summarize site remediation activities to date, present the results of the October 1997 system monitoring event and compare them with the results of the earlier pilot testing events, and to recommend future remediation activities for the site based on these findings.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Nov 20, 1997
Accession Number
ADA385100

Entities

Organizations

  • Parsons Corporation

Tags

Communities of Interest

  • Human Systems

DTIC Thesaurus Topics

  • Air Flow
  • Air Force
  • Air Force Facilities
  • Biodegradation
  • Carbon Dioxide
  • Chemistry
  • Contamination
  • Contractors
  • Department Of Defense
  • Engineering
  • Environmental Protection
  • Flow
  • Flow Rate
  • Fuels
  • Groundwater
  • Measurement
  • Monitoring

Fields of Study

  • Environmental science

Readers

  • Environmental Remediation and Restoration.