Extended Bioventing Testing Results at the BX Service Station Site, Patrick AFB, Florida
Abstract
Parsons Engineering Science, Inc. (Parsons ES) is pleased to submit the results of the extended bioventing testing at the BX Service Station Site at Patrick Air Force Base (AFB), Florida. Soil gas samples were collected, and in situ respiration testing was performed by Parsons ES from 8 to 14 November 1996 to assess the extent of remediation completed during approximately 3 months of soil vapor extraction (SVE), 1.5 years of pilot-scale air injection bioventing, and 1 year of full-scale air injection bioventing. The purpose of this letter is to summarize site and remediation activities to date, present the results of the most recent respiration testing and soil gas sampling, and make recommendations based on site data. A site layout figure and three tables are attached. The as-built bioventing system and sampling/respiration testing locations are illustrated on Figure 1. Table 1 summarizes soil analytical results. Table 2 provides a summary of soil gas sampling results, and Table 3 provides a summary of. respiration testing results for the site.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 20, 1997
- Accession Number
- ADA385534
Entities
People
- Ed Marchand
Organizations
- Parsons Corporation