Soil Vapor Extraction and Bioventing Test Work Plan for the MOGAS Site, Myrtle Beach Air Force Base, South Carolina

Abstract

This work plan presents an evaluation of soil vapor extraction (SVE) and bioventing, and describes the SVE pilot scale and bioventing activities to be conducted to extract and treat soil gas at Installation Restoration Program (IRP) Site SS-20 located at Myrtle Beach Air Force Base (AFB), Myrtle Beach, South Carolina. Site SS-20, locally known as the MOGAS site, is known to be contaminated with fuel hydrocarbons. The SVE pilot scale tests will use an internal combustion engine (ICE) system with advanced emission controls VR systems(R), and the Ultrox ultraviolet (UV)/Oxidation D-TOX(TM) system. The proposed SVE pilot tests will be conducted in two phases.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1995
Accession Number
ADA386010

Entities

Organizations

  • Parsons Corporation

Tags

Communities of Interest

  • Human Systems

DTIC Thesaurus Topics

  • Air Force
  • Air Force Facilities
  • Biodegradation
  • Carbon Dioxide
  • Combustion
  • Construction
  • Department Of Defense
  • Efficiency
  • Emission Control
  • Engineering
  • Environmental Protection
  • Fire Extinguishers
  • Groundwater
  • Installation Restoration
  • Internal Combustion Engines
  • South Carolina
  • Volatile Organic Compounds

Fields of Study

  • Environmental science

Readers

  • Groundwater Contamination Remediation.
  • Oceanography.