Results of Bioventing System Monitoring at Eglin Main Base Old Fire Training Area (Site FT-28), Eglin Air Force Base, Florida
Abstract
This letter presents the results of the bioventing system monitoring performed by Parsons Engineering Science, Inc. (Parsons ES) during the week of 8 February 1999 at the Eglin Main Base Old Fire Training Area (old Eglin FTA) at Eglin Air Force Base (AFB), Florida. This site is also identified as Installation Restoration Program (IRP) Site FT-28. Soil gas samples were collected and in situ respiration testing was performed by Parsons ES to assess the extent of remediation completed during approximately 1 year of expanded-scale bioventing system operation. The purpose of this letter is to summarize site and bioventing activities to date, present the results of the most recent respiration testing and soil gas sampling event, and make recommendations based on site data. A site layout and three tables are attached. Attachment A contains tables and graphs that were employed for calculations.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 16, 1999
- Accession Number
- ADA386471