Thermal Management Research Studies. Volume 2: Experimental Investigation of Oscillating Heat Pipes for Actuator Cooling

Abstract

Operation requirements of oscillating heat pipes (OHPs) were proposed. Based on the requirements, OHPs with acetone and nonflammable fluorocarbon fluids, FC-72 and FC-75, as the working fluid were developed. The OHPs had 40 tubing turns formed from a copper tubing with an inner diameter of 1.75 mm and a total length of 18.61 m. The OHPs were formed in the shape of a planer array that was 256-min wide and 446mm high. There were two condensers on both outer sides and one evaporator in the middle of the OHPs. Thermal performance tests were conducted at various operating temperatures and heat rates. The working fluid fill ratio was varied The OHPs with acetone and FC-72 exhibited their highest heat transport performance in excess of 2000 W without dryout. This is the first time that such a performance was demonstrated. The gravitational acceleration did not have noticeable influence on the performance of the OHPs. The thermal performances of the fluorocarbon OHPs were compared with the case of the acetone OHP.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Mar 01, 2001
Accession Number
ADA390062

Entities

People

  • Lin Lanchao

Organizations

  • Universal Energy Systems

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Actuators
  • Air Force
  • Air Force Research Laboratories
  • Conduction (Heat Transfer)
  • Energy
  • Energy Storage
  • Flow Rate
  • Heat Energy
  • Heat Pipes
  • Heat Transfer
  • Heat Transfer Coefficients
  • Heat Transfer Devices
  • Measurement
  • Performance Tests
  • Pipes
  • Temperature Control
  • Tubes

Readers

  • Combustion and Flow Dynamics.