An Advanced NDE Technique for Agile Manufacturing
Abstract
In this project, ARACOR developed the Konoscope(Trademark) volumetric x-ray computed tomography (CT) system (the Konoscope). Unlike conventional CT systems, which acquire data one slice at a time, the Konoscope acquires all the necessary data at one time. This approach significantly accelerates the collection of the CT data required for image production, especially for high- resolution scanning. The Konoscope employs an x-ray cone beam and an area detector, rather than the fan beam and linear detector used in conventional CT systems. Technological advancements made during the project and incorporated in the Konoscope include: 1. A bright x-ray source using an ARACOR diamond anode BRATTTM (BRight Anode Transmission Target) target 2. A high-performance area detector 3. A helical scan geometry for acquiring volumetric data 4. The parallel processing of optimized reconstruction software for timely reconstruction of large, volumetric data sets.
Document Details