Fragment-Field Analysis Testing System
Abstract
Physical Sciences Inc. (PSI) developed for the USAF Air Armament Center (AAC), Eglin AFB an arena test explosive warhead fragment characterization system. PSI's FRagment-Field Analysis Testing (PRAT) system records a spatial impact location to an accuracy of approximately 1% of the screen area with a resolution time of 1 microsecs. PSI's innovative approach detects impact locations by encoding an electrical signal that is location dependent. PSI's FRAT system provides substantial improvements over the current system, by better distinguishing between intermittent contacts of the same fragment and multiple fragments as well as recording simultaneous fragment impacts on the same impact switch screen. Spatially and temporally resolved fragment impacts can then be correlated with recovered fragment masses. The fragment mass and impact characterization data coupled with an existing computational model, produces range dependent representations of fragment velocity, momentum, and kinetic energy of warhead fragments. PSI's PRAT system also furnishes electronic interfaces with AAC's Test Data Visualization System for enhanced data presentation.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 2000
- Accession Number
- ADA405521
Entities
People
- Peter Nebolsine
- Richard C Barnard
Organizations
- Physical Sciences (United States)