Development of a Minimum Performance Standard for Hand-Held Fire Extinguishers as a Replacement for Halon 1211 on Civilian Transport Category Aircraft

Abstract

One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer and production of new Halon 1211 has been halted per the Montreal Protocol in 1993. The phase out of Halon 1211, as the hand-held firefighting agent of choice, for civilian transport category aircraft has necessitated the development of a Minimum Performance Standard (MPS) to evaluate replacement agents. The purpose of the MPS is to insure that there is no reduction in safety, both in terms of effectiveness in fighting onboard fires and toxicity to the passengers and crew. The MPS specifies two new tests that replacement agents must pass in addition to requiring national certifications such as provided by Underwriters Laboratories. The first test evaluates the "flooding" characteristics of the agent against a hidden in-flight fire. This test determines the ability of a streaming agent to function as a flooding agent. The second test evaluates the performance of the agent in fighting a terrorist fire scenario and the associated toxicity hazard. This test measures the agent's ability to extinguish a triple-seat fire in an aircraft cabin under in-flight conditions and the toxicity characteristics of both the neat agent and the products of decomposition. This MPS will insure that the replacement agents will meet or exceed the performance of Halon 1211 both in fighting fires and maintaining a safe breathing environment in aircraft cabins.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Aug 01, 2002
Accession Number
ADA408024

Entities

People

  • Harry Webster

Tags

DTIC Thesaurus Topics

  • Aircraft Cabins
  • Aircrafts
  • Decomposition
  • Dielectric Gases
  • Fire Extinguishers
  • Fire Extinguishing Agents
  • Floods
  • Great Lakes
  • Instrumentation
  • Performance Tests
  • Safety
  • Solenoid Valves
  • Test Fixtures
  • Test Methods
  • Three Dimensional
  • Toxicity
  • Transport Aircraft

Readers

  • Fire Suppression Systems Design.
  • Systems Analysis and Design