The Effects of LOX Post Biasing on SSME Injector Wall Compatibility
Abstract
An experimental investigation has been carried out to examine the effects of LOX post biasing of a shear coaxial injector on the behavior of the spray near a chamber wall. The experimental work was performed with inert propellant simulants in a high-pressure chamber. Injector flow rates and chamber pressure were designed to match the Space Shuttle Main Engine (SSME) injector gas-to-liquid density and velocity ratio at the point of propellant injection. Measurements of liquid mass flux, gas phase velocity and droplet size were made using mechanical patternation and phase Doppler interferometry techniques. The measurements revealed that the liquid mass flux distribution shifts away from the wall with increasing LOX post bias away from the wall. The shift in the liquid flux distribution was much greater than that caused by the angling of the LOX post alone. Gas velocity near the wall simultaneously increased with increasing LOX post bias away from the wall. The increase in wall side gas velocity was due to the higher fraction of gas injected on the wall side of the injector as a result of the eccentricity at the injector exit. The net result was a decrease in mixture ratio near the wall. Estimates of heat transfer and engine performance relative to the unbiased case are presented.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 19, 1999
- Accession Number
- ADA410025
Entities
People
- Douglas G. Talley
- K. L. Miner
- L. K. Tseng
- P. A. Strakey
Organizations
- Air Force Research Laboratory