Automatic Coulometric Titration of Sulfuric Acid in Chromium Plating Solutions
Abstract
No specific chemical analysis method exists in the literature for the offline or online determination of sulfuric acid in chromium plating solutions by automatic coulometer titration. A method is presented here that provides somewhat acceptable analysis and monitoring of the sulfuric acid in this chromium plating process. Due to a subjective data reduction process, online application of this method is unacceptable. The optimum operating range of sulfinic acid is 2.40- 3.10 g/l and the resulting precisions by this method are in the range of 0.10-0.25 g/I. These resulting offline automatic titration precisions are nearly equal to the presently used automatic ion chromatography precisions which is still the best available method to date.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1991
- Accession Number
- ADA420010
Entities
People
- Samuel Sopok
Organizations
- United States Army Armament Research, Development and Engineering Center