Xenon Spectral Gamma Penetrometer Probe Characterization and Calibration
Abstract
Ex situ analysis to characterize subsurface media for gamma-emitting radionuclides is time-consuming and costly. A Site Characterization and Analysis Penetrometer System (SCAPS) spectral gamma penetrometer probe was designed using newly developed small-diameter high-pressure xenon gas gamma ray detector technology for the in situ speciation (identification) and quantification of subsurface gamma-emitting contaminants. This report documents the design calibration laboratory studies and functionality field demonstration conducted to characterize the capabilities and limitations of the xenon spectral gamma probe. Results and comparative analysis of side-by-side simultaneous laboratory investigation/evaluation studies using SCAPS xenon spectral gamma and sodium iodine spectral gamma probes are also documented.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 2004
- Accession Number
- ADA428245
Entities
People
- Charles A. Sparrow
- John C. Morgan
- John H. Ballard
Organizations
- Engineer Research and Development Center