Ventilating Cathedral Ceilings to Prevent Problematic Icings at Their Eaves

Abstract

Building heat from an unventilated steep-slope roof system can cause bottom melting of snow on that roof's surface. This often creates icicles, ice dams, leaks and structural damage at cold eaves. A prior study of attics showed that, to minimize such problems, attic ventilation systems should be sized to keep the underside of the roof below freezing when it is 22 F (-5.6C) outside. When it is colder than that, it is easier to ventilate with outside air, and when it is warmer than 22 F(-5.6 C) meltwater seldom refreezes at eaves. In this paper, mathematical expressions for sizing airways of cathedral ceilings of various slopes, lengths and insulating abilities are presented. Coldroom tests of 16 food- (4.9-m-) long airways, some undersized and some oversized, show that the mathematics produces airways that do indeed perform as expected. In some of these tests, airways were blocked by expanding fibrous glass insulation. Air barriers and rigid insulation boards are shown to offer solutions to this problem. Design guidelines in the form of graphs make the taste of sizing cathedral ceiling airways, as well as their inlet and exhaust openings, quick and easy.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Sep 01, 1999
Accession Number
ADA433980

Entities

People

  • James Buska
  • Thomas Tantillo
  • Wayne Tobiasson

Organizations

  • Cold Regions Research and Engineering Laboratory

Tags

DTIC Thesaurus Topics

  • Abstracts
  • Availability
  • Classification
  • Cold Regions
  • Contracts
  • Engineering
  • Equations
  • Freezing
  • Heat Energy
  • Information Operations
  • Instructions
  • Insulation
  • Mathematics
  • Monitoring
  • Regions
  • Standards

Readers

  • Computer Engineering
  • Energy Conservation and Renewable Energy Engineering.
  • Polar and Arctic Studies

Technology Areas

  • Microelectronics