Characteristics and Sampling Efficiencies of SpinCon and Pre-Production Omni Model Aerosol Samplers
Abstract
Characteristics and aerosol sampling efficiencies of one SpinCon and two pre-production (PP) Omni model aerosol samplers Omni-2 and Omni-3) (Sceptor Industries, Inc., Kansas, MO) were determined at the U.S. Army Edgewood Chemical Biological Center. All three samplers have non-traditional wetted-wall cyclones to collect and concentrate aerosols in liquid. The Omni aerosol sampler is designed to be approximately half the weight, half the size, and a quarter of the power of the SpinCon. The sampling efficiency tests were conducted with monodisperses 1- and 3-um fluorescent polystyrene latex (PSL) microspheres and 3.5- and 5-um fluorescent oleic acid particles.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 2006
- Accession Number
- ADA458159
Entities
People
- Deborah R. Schepers
- Jana S. Kesavan
Organizations
- Edgewood Chemical Biological Center