Operation of a Low-Voltage High-Transconductance Field Emitter Array TWT
Abstract
Implementation of "cold cathodes" as an electron source for RF vacuum devices can have a significant impact on many aspects of device operation. Cold Cathode Impact on RF Device Operation: No cathode wearout mechanism * Room temperature operation * Eliminate heater power * High current density operation * Instant turn-on * Eliminate HV modulator * Multi-mode operation * Infinite ON/OFF isolation * Device miniaturization * Increased interaction efficiency * Improved linearity * Decreased harmonic power.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 2008
- Accession Number
- ADA482840
Entities
People
- C. A. Spindt
- C. L. Bellew
- C.E. Holland
- C.M. Armstrong
- D. R. Whaley
- R. Duggal