Crash Cooling Treatment of T.N.T. Effluents

Abstract

A pilot plant for the treatment of the effluents from the T.N.T. purification house has been designed, erected and operated to obtain data for the design of full scale units. The treatment involves continuous "Crash Cooling" of the hot effluent in a heat exchanger of the stirred vessel type, using a gate paddle stirrer with small clearance between the paddle and the coil. Coils fabricated from lead, stainless steel and mild steel were tried out.