Use of Primary Frequency Standards for Estimating the Duration of the Scale Unit of TAI
Abstract
The accuracy of International Atomic Time TAI is based on a small number of primary frequency standards (PFS) that aim at realizing the SI second, the unit of proper time. Following the 14th meeting of the Consultative Committee for Time and Frequency (April 1999), the BIPM time section is reconsidering how the PFS comparisons are used for evaluating the duration of the scale unit of TAI, uTAI, and how they are reported in Circular T and other BIPM publications. In the new procedure, it is proposed to break down the estimation of the uncertainty of the comparison in several elementary components and to report all of them in the BIPM publications in order to make the uncertainty evaluation more transparent and traceable. The BIPM also regularly computes an estimation of the duration of the scale unit of TAI using an accuracy algorithm combining the data of all PFS. The parameters used in this algorithm are re-evaluated and a new estimation of u(TAI) has been carried out over the recent years. The standard uncertainty on this value is now estimated to be 3x10(-15).
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1999
- Accession Number
- ADA497644
Entities
People
- G. Petit
Organizations
- International Bureau of Weights and Measures