Time Signal Distribution in Communication Networks Based on Synchronous Digital Hierarchy
Abstract
A new method that uses round-trip paths to accurately measure transmission delay for time synchronization is proposed. The performance of the method in Synchronous Digital Hierarchy networks is discussed. The feature of this method is that it separately measures the initial round- trip path delay and the variations in round-trip path delay. The delay generated in SDH equipment is determined by measuring the initial round-trip path delay. In an experiment with actual SDH equipment, the error of initial &lay measurement was suppressed to 30ns.
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1992
- Accession Number
- ADA501935
Entities
People
- Atsushi Imaoka
- Masami Kihara
Organizations
- NTT, Inc.