Vapor Pressure of Cyclohexyl Methylphosphonofluoridate (GF)
Abstract
The vapor pressure of cyclohexyl methylphosphonofluoridate (also known as cyclosarin or GF has been measured between 0 and 40 degrees C using vapor saturation methodology. The current data indicate that the volatility of GF is higher than projected based on data previously measured by ca. 20% at 25 degrees C and more than twice as high at -10 degrees C.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 2009
- Accession Number
- ADA503835
Entities
People
- David E. Tevault
- James H. Buchanan
- Kathy L. Matson
- Leonard C. Buettner
Organizations
- Edgewood Chemical Biological Center