Storage of Limited Quantities of Explosives at Reduced Q-D
Abstract
Department of Defense installations often desire storage locations for limited quantities of explosives which may exceed existing Q-D requirements. Department of Defense Explosive Safety Regulations (DOD 6055.9) and implementing Army regulations (AR 385-64) require safety zones based on a 670 foot arc for quantities of explosives up to 100 pounds and 1250 feet minimum for higher quantities. These default limits can impose a severe burden on installations. A limited explosive quantity storage magazine design has been completed in support of the Army's Safeload program which can be sited at reduced Q-D limits. The Mini Magazine has been designed to be consistent with approved DOD and Army design criteria. The Mini Magazine will be of great benefit to those requiring limited storage of explosives in congested areas.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1994
- Accession Number
- ADA514148
Entities
People
- James P. Manthey
- R. S. Wright
Organizations
- United States Army Corps of Engineers