Reduction of Hazard Zones by Uncoupling Between Munitions

Abstract

For determining the Maximum Credible Event concerning a munitions production or storage facility, it is necessary to take account of the N.E.Q. of all the mass detonating munitions located in the immediate neighbourhood of the donor. Safety distances which will be determined (Q/D factor) will be those of 1.1 division. This risk division induces highest constraints. Uncoupling between munitions allows to reduce safety distances with important benefits by suppressing sympathetic detonation. Different means can be used, specially like specific packaging, venting devices, or intrinsic characteristics of insensitive munitions. This paper shows tests realized by GIAT Industries / Ammunition and Pyrotechnics Division with different types of munitions and main results obtained.