Evaluation of Operator Protection from Remote Operations in Existing Buildings with 12-Inch Substantial Dividing Walls (SDWs)
Abstract
Procedures to relate Net Explosive Weights (NEWS) to combinations of intervening 12-inch Substantial Dividing Walls (SDWs) to provide protection to personnel from remote operations has been developed. Protection is IAW DoD and Army policy: 2.3 psi maximum overpressure exposure and no hazardous fragments. The procedures are reported in a two-volume guide: Volume I is a "how to" guide for installation use, and Volume II is the rationale behind Volume I. Protection from thermal effects (flash fire, deflagration, etc.) is not addressed. The guide is a "simple-to-use stand-alone" document that can be used by operating contractors and installation personnel. This paper summarizes key features of the guide and provides an example problem using the guide methodology.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1992
- Accession Number
- ADA526662
Entities
People
- Adib R. Farsoun