Characteristics of Twenty-Nine Aerosol Samplers Tested at U.S. Army Edgewood Chemical Biological Center (2000-2006)

Abstract

A summary is given for 29 aerosol samplers evaluated by the Aerosol Sciences Branch at the U.S. Army Edgewood Chemical Biological Center from 2000 - 2006. A one-page summary is shown for each sampler with the description, a picture, specifications, and sampling efficiencies of that sampler. An example comparative subjective ranking methodology is provided for the readers to modify and use.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Feb 01, 2011
Accession Number
ADA540009

Entities

People

  • Deborah Schepers
  • Jana S. Kesavan
  • Jerold Bottiger

Organizations

  • Edgewood Chemical Biological Center

Tags

Communities of Interest

  • Counter WMD
  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Communication Systems
  • Efficiency
  • Electrical Properties
  • Energy Consumption
  • Flow Rate
  • Fungi
  • High Voltage
  • Materials
  • Oleic Acid
  • Particle Size
  • Particles
  • Porous Metals
  • Sampling
  • Separators
  • Specifications
  • Standards
  • Universities

Readers

  • Aerosol Science/Aerosol Physics
  • Library and Information Science
  • Systems Analysis and Design