AM2 3-4 Alternate Lay Pattern Evaluation

Abstract

AM2 airfield matting has a long history of successful performance as an expeditionary airfield surfacing system. Logistical considerations for shipment of AM2 by the U.S. Marine Corps require equal numbers of 6-ft and 12-ft-long AM2 panels to be delivered to all project sites, resulting in far more 6-ft panels than are necessary to create a standard brickwork pattern. Therefore, the 3-4 alternate lay pattern was designed to allow Marines to use any mats on hand to fill in designated portions of the matted areas. Using the 3-4 pattern, as many as six continuous longitudinal joints are allowed, compared to only one with a brickwork pattern. A test section was constructed using the 3-4 pattern and trafficked by simulated F-15E and C-17 traffic. The test results showed a reduction in allowable passes of 92 to 96% when compared to the brickwork pattern for an installation directly over a subgrade with a California Bearing Ratio of 6. Based on these results, the 3-4 pattern is not recommended for runways or high-speed taxiways, nor for soft soil installations.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Sep 01, 2014
Accession Number
ADA610771

Entities

People

  • Craig A. Rutland
  • Jeb S. Tingle
  • Lyan Garcia
  • Paul G Allison
  • Timothy W. Rushing

Organizations

  • Engineer Research and Development Center

Tags

Communities of Interest

  • Counter WMD

DTIC Thesaurus Topics

  • Air Force
  • Aircrafts
  • Civil Engineering
  • Construction
  • Engineering
  • Engineers
  • Failure Mode And Effect Analysis
  • Gages
  • Landing Fields
  • Materials
  • Measurement
  • Moisture Content
  • Standards
  • Strain Gages
  • Test And Evaluation
  • Test Facilities
  • Test Methods

Readers

  • Maritime Combat Support and Expeditionary Logistics.
  • Pavement Materials Engineering.