Operation of NRL Homopolar Generator into Parallel Energy Storage Inductor
Abstract
A 170-mu H solenoid has been constructed and used as an energy storage inductor with the existing NRL self-excited HPG. This use of a separate energy storage coil results in minimal interaction with the excitation coil and permits operation at higher voltages. The energy storage inductor has been designed to operate under water at a megavolt. The circuit and energizing of the two parallel inductors is described. The inductive storage has been used in conjunction with opening switches to generate output pulses with 30-(mu)s risetime and an e-fold decay time determined by the load resistance.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 2013
- Accession Number
- ADA636726
Entities
People
- D. Jenkins
- I. M. Vitkovitsky
- R. D. Ford
- W. H. Lupton
Organizations
- United States Naval Research Laboratory