Comparison of Experimental Data to that of a Semiempirical Model for Helical MCG's
Abstract
A semi-empirical model of helical magnetocumulative generators (MCGs) has been developed. Two constants that are independent of the type of helical generator and the nature of the load and a single adjustable variable (the characteristic time) have been identified. To verify this model, calculated results were compared to experimental data for four helical MCGs - the Mark IX, FLEXY-I, EF-3, and Ranchito generators. The calculated results are in good agreement with the experimental data, as well as those generated by other codes.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 2001
- Accession Number
- ADA639339
Entities
People
- Larry L. Altgilbers
- P. T. Tracy
- Ya. Tkach