Operation of a Five-Stage 40,000-CM2-Area Insulator Stack at 158 kV/CM

Abstract

We have demonstrated operation of a 3.35m-diameter insulator stack at 158 kV/cm with no total-stack flashovers on five consecutive Z-accelerator shots. The stack consisted of five +45 -profile 5.715-cm-thick crosslinked- polystyrene (Rexoiite-1422) insulator rings, and four anodized-aluminum grading rings shaped to reduce the field at cathode triple junctions. The width of the voltage pulse at 89% of peak was 32 ns. We compare this result to a new empirical flashover relation developed from previous small-insulator experiments conducted with flat unanodized electrodes.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1999
Accession Number
ADA639384

Entities

People

  • F. W. Long
  • H. C. Ives
  • John W. Douglas
  • M. L. Horry
  • R. A. Anderson
  • R. B. Spielman
  • Robert E. Clark
  • T. L. Gilliland
  • Thomas P. Hughes
  • W. A. Stygar

Organizations

  • Sandia National Laboratories

Tags

Communities of Interest

  • Advanced Electronics

DTIC Thesaurus Topics

  • Charged Particles
  • Diameters
  • Dielectric Polymers
  • Dielectrics
  • Electrodes
  • Electromagnetic Fields
  • Geometry
  • Magnetic Fields
  • Materials
  • Measurement
  • Plastics
  • Probability
  • Pulsed Power
  • Radiation
  • Resins
  • Thickness
  • Ultraviolet Radiation

Fields of Study

  • Physics

Readers

  • Electrical Engineering
  • Mathematics or Statistics

Technology Areas

  • Microelectronics