Two-Axis Angular Rate and Acceleration Multisensor Test
Abstract
Two Litton MS-4 Multisensors, S/N 17 and S/N 23 were tested at the Central Inertial Guidance Test Facility, 6585th Test Group, Holloman AFB, New Mexico during the period from November 1973 to June 1975. The purpose of the tests was to collect performance and environmental data on the instruments. The laboratory tests included gyro and accelerometer coefficient determination; drift tests; voltage, frequency and temperature sensitivity tests; and scale factor linearity tests. A hot soak was the only environmental test performed due to failure of one instrument and damage to the other. The report contains test results for the complete laboratory phase of testing on Multisensor S/N 17 and results of coefficient determination and drift tests on Multisensor S/N 23.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1975
- Accession Number
- ADB006597
Entities
People
- Craig H. Price
- Richard E. Rumph
- Robert R. Thede
Organizations
- Air Force Special Weapons Center