Two-Axis Angular Rate and Acceleration Multisensor Test

Abstract

Two Litton MS-4 Multisensors, S/N 17 and S/N 23 were tested at the Central Inertial Guidance Test Facility, 6585th Test Group, Holloman AFB, New Mexico during the period from November 1973 to June 1975. The purpose of the tests was to collect performance and environmental data on the instruments. The laboratory tests included gyro and accelerometer coefficient determination; drift tests; voltage, frequency and temperature sensitivity tests; and scale factor linearity tests. A hot soak was the only environmental test performed due to failure of one instrument and damage to the other. The report contains test results for the complete laboratory phase of testing on Multisensor S/N 17 and results of coefficient determination and drift tests on Multisensor S/N 23.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Aug 01, 1975
Accession Number
ADB006597

Entities

People

  • Craig H. Price
  • Richard E. Rumph
  • Robert R. Thede

Organizations

  • Air Force Special Weapons Center

Tags

Communities of Interest

  • Sensors
  • Weapons Technologies

DTIC Thesaurus Topics

  • Accelerometers
  • Air Force
  • Coefficients
  • Control Panels
  • Electronics
  • Environmental Tests
  • Excitation
  • Frequency
  • Guidance
  • Laboratory Tests
  • Resonant Frequency
  • Sensitivity
  • Standards
  • Temperature Control
  • Test And Evaluation
  • Test Equipment
  • Test Facilities

Readers

  • Aerospace Test and Evaluation
  • Inertial Navigation Systems.