Operational Testing of a System for Solid Waste to Energy Conversion
Abstract
A performance evaluation based on 48 hours monitoring of a packaged heat recovery incinerator installation is presented. The evaluation includes heat balance analysis, stack emissions, and general observations. The heat balance data is of greatest significance since it will allow extrapolation of heat balances for other operating conditions.
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 01, 1976
- Accession Number
- ADB017044
Entities
People
- H. G. Rigo
- H. Kleinhenz