Abstract
Two nominally independent analytical calibration techniques have been developed for each of the F/A-18 horizontal stabilator and wing fold "Maintenance Signal Data Recording Set" (MSDRS) sensors. Repeatable and consistent results over different flying periods, with good statistical correlation values, were achieved for the candidate RAAF aircraft considered. Scaling factors were also calculated for Canadian Forces aircraft used in the International Follow On Structural Test Program spectra development. These techniques will enable scale factors, defined as the ratio of the responses between two gauges positioned at nominally identical locations on different aircraft, to be calculated using operational MSDRS data. These results will allow comparisons to be made between aircraft in terms of operational usage or agamst fatigue test results. (MM)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1995
- Accession Number
- ADB205094
Entities
People
- L. Molent
- R. W. Ogden
- Y. G. Ooi
Organizations
- Defence Science and Technology Group