Development Test III of Quick Look II AN/ALQ-133.

Abstract

The QUICK LOOK II system met the critical issues/criteria except for the following: technical performance of the interim processor, reliability, manuals and spare parts were found to be deficiencies. Shortcomings were noted in the technical performance areas of system sensitivity, desensitization, fix accuracy, signal security and vulnerability, availability, maintainability, pod carrier, AN/ALM-153 instrumentation, BITE system performance, safety, and human factors. Despite the deficiencies and shortcomings noted, the nature of the discrepancies and the overall performance of the system merits its continued correction and evaluation. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1978
Accession Number
ADC014768

Entities

People

  • Carleton W. Nellis

Tags

DTIC Thesaurus Topics

  • Accuracy
  • Availability
  • Deficiencies
  • Instrumentation
  • Maintainability
  • Measuring Instruments
  • Reliability
  • Security
  • Sensitivity
  • Spare Parts
  • Test And Evaluation
  • Vulnerability

Readers

  • Aerospace Test and Evaluation