Preliminary Report on Diffuser-Screen Combinations for Reducing Wind-Tunnel Turbulence

Abstract

Experiments were conducted on single screens, diffuser-screen combinations, turbulence reduction, and effects of screens on flow in diffuser. As many screens as possible may be used consistent with allowable reduction in energy ratio of the tunnel. Arrangement of many screens with low K (pressure drop coefficient of screen) is more efficient than one of few screens with high K value. Turbulence reduction depends only on area of diffuser when screens are selected and located for zero over-all pressure drop.