Preliminary Design Procedure for Reinforced Concrete Flat Slabs,
Abstract
The objective of this report is to outline the preliminary flat slab design procedure for impulse-sensitive structures and to summarize the test results that support changes to the ultimate deflection criteria given in P-397 for concrete structures without lacing reinforcement. A final design procedure with examples will be published with examples will be published this year. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1982
- Accession Number
- ADP000470
Entities
People
- James E. Tancreto
Organizations
- Naval Facilities Engineering Service Center