Metal Forming and Inspection Control for Cable Sheathing,

Abstract

Development by Western Electric Company has resulted in a unique quality measurement system based upon the 'percent take-up' and 'build-up' of a cable sheath. Percent take-up is defined as the amount of useable metal remaining in the cable sheath after metal forming and Build-up is defined as the amount of spacing, due to the metal, between the polyethylene jacket and the conductor core. In the development of a quality control system, a direct relationship between the existing shop specifications and the new specifications involving build-up and percent take-up were established. With these requirements, the manufacturing window was effectively doubled and the quality level improved in cable products. Resulting parameters are measurable in all finished products and provide a quick feedback of cable quality guaranteeing a quality level exceeding the present standards (8X bend). (Author)

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1982
Accession Number
ADP000542

Entities

People

  • Dan E. West
  • William D. Bohannon Jr.

Tags

DTIC Thesaurus Topics

  • Closed Loop Systems
  • Control Systems
  • Dielectric Polymers
  • Feedback
  • Inspection
  • Manufacturing
  • Measurement
  • New Jersey
  • Quality Control
  • Specifications
  • Standards

Readers

  • Electrical Engineering
  • Polymer Science and Engineering.
  • Software Engineering

Technology Areas

  • Space