Design Criteria and Preliminary Acceptance Test Specifications for Blast Resistant Windows
Abstract
Preliminary design criteria for blast resistant windows exposed to blast overpressures up to 25 psi are recommended. Design procedures and design curves for fully tempered glass are presented and parametized according to glass thickness, glass dimensions, glass aspect ratio, peak blast overpressures, and effective blast duration. Curves for annealed glass are also presented for the purpose of analyzing the safety of existing structures. Design criteria for frames and a test certification procedure are also discussed. Additionally, design examples are presented.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1984
- Accession Number
- ADP004825
Entities
People
- Gerald E. Meyers
Organizations
- Naval Facilities Engineering Service Center