ELECTROINTERFERENCE EVALUATION OF THE ATLAS MA-5 ELECTRICAL SYSTEM

Abstract

The results of radio noise tests performed on the Atlas MA-5 electrical system are presented. Conducted interference measurements using a stabilization network were made from 150 kilo cycles to 25 megacycles. Conducted interference measurements using a current probe were made from 30 cps to 25 megacycles. Radiated interference measurements were made in the frequency range of 15 kilocycles to 400 mega cycles. The MA-5 engine electrical system is within specification limits between 30 and 15 kilocycles in the conducted interference portion of the test. In other portions of the test, the interference levels measured varied, with the majority of the measurements above specified limits.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
May 01, 1963