STRUCTURAL MATERIALS FOR HARDENED PERSONNEL SHELTERS
Abstract
Structural materials are evaluated for use in fully-buried personnel shelters, located above the ground water table. Analytical relationships are supplied for the structural elements of these shelters, assuming shelter configurations of a rectangular cubicle, a horizontal 180 degree arch and full cylinder, and a 180 degree dome and full sphere. In-place costs are derived for suitable structural materials, and cost equations are supplied for estimating the in-place cost of structural elements. Various structural units are used in preparing alternative designs for a 100-man capacity shelter in the 10 to 200 psi over-pressure region. Cost trends are indicated, and minimum structural costs are related to design level of overpressure.
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1963
- Accession Number
- AD0429134
Entities
People
- John A. Havers
Organizations
- IIT Research Institute