ANALYSIS AND DESIGN OF CBR PROTECTION FOR THE AN/TRQ-47 SYSTEM
Abstract
This document covers the analysis and design of CBR protection for AN/TSQ-47 system shelters. Standard CBR protection components were selected based on Category A protection requirements and a shelter system analysis. The E46R7 filter unit, Q-38 protective entrance (short), and E31 anti-backdraft valve, each with minor modifications, are the recommended CBR protection components. In addition, a booster blower unit is required in the shelter recirculation system to reduce shelter pressure. Components are sized based on assumed leakage and pressure drop characteristics. The values assumed are considered to be within 10% of actual values. Tests are defined to verify the assumptions if verification is considered necessary.